What color is fireproof coating for steel structures?


Release date:

2022-10-08

Author:

Zhengxiang Fireproof Materials

Fire-resistant coatings for steel structures enhance a building’s fire resistance and offer toughness and wear resistance. As public awareness of fire safety grows, the number of steel components coated with fireproofing has increased rapidly. The color of steel fire-resistant coatings should also be differentiated according to the specific application.

  Fire-resistant coatings for steel structures enhance a building’s fire resistance and offer toughness and wear resistance. As public awareness of fire safety grows, the number of steel components coated with fireproofing has increased rapidly. Fireproof coating for steel structures The colors should also be differentiated according to the specific location.

  

f6fae535-c139-4dd4-9356-3669f1ae0078.jpg


  Steel structure fireproof coatings (Nb(bt-02)) come in many colors, but they are generally monochromatic. Some cannot be adjusted at all. This is because certain fire-resistant materials are inherently colored, so the coating can only retain the material’s original or similar hue, leaving little room for mixing. Common steel structure fireproof coatings include white, light yellow, gray, and black. If you wish to achieve other colors—such as bright red, purple, dark blue, or orange—these cannot be adjusted. Steel structure intumescent thin‑film fireproof coatings are special coatings applied to combustible substrates; they reduce the flammability of the coated surface, slow the rapid spread of fire, and increase the fire resistance duration of the substrate.

   Fireproof coating for steel structures Different colors are used in different settings. Before applying the thin intumescent fireproof coating Nb(bt-02), the substrate surface must be cleaned. If the substrate is already painted, it should be stripped or polished with wet sandpaper, and painting can only proceed after the surface has been exposed. Each coat should be 0.2–0.3 mm thick, with an interval of 8–12 hours between applications. In humid conditions with high air humidity, the time between coats may be extended as needed; apply the next coat only after the previous one has dried. When applying fireproof coatings to steel structures, ensure that the interior fire-resistant coating film is smooth and even.

  The advantages of interior steel structure fireproof coatings are that they are environmentally friendly and odorless, posing no health risk to applicators. After application and spraying, a comprehensive inspection should be carried out to ensure trouble-free operation upon commissioning.

  The coating of the Nb(bt-02) thin intumescent fireproof coating for indoor steel structures shall meet the following requirements:

  1. The coating thickness of interior fireproof coatings for steel structures shall comply with the design requirements.

  2. Indoor Fireproof coating for steel structures There shall be no areas of missed coating, powder flaking, or visible cracks. If individual cracks are present, their width shall not exceed 0.5 mm.

  3. The coating shall be firmly bonded to the steel substrate, with no delamination, hollowness, or other defects in any layer.

  4. The color and appearance meet the design requirements, with clear contours and smooth transitions.

  The NH(BT-03) coating for indoor thick-type steel structure fireproofing shall meet the following requirements:

  1. The thickness of the thick‑coat fire‑protective coating on indoor steel structures shall comply with the design requirements. For coatings thinner than the original standard, the thickness shall not be less than 85% of the original standard, and the length of any continuous area where the specified thickness is not met shall not exceed 1 m; no similar deficiencies shall occur within a 5‑m range.

  2. The coating shall be continuous, with no exposed areas or missed spots;

  3. The fireproof coating for indoor steel structures shall be firmly bonded to the steel substrate, with no hollowness, delamination, or looseness in any coating layer.

  4. The surface of the fireproof coating on indoor steel structures shall be free of protrusions; for areas with appearance requirements, the allowable deviation in straightness and out-of-roundness of busbars shall not exceed 8 mm.