How should fire-resistant coatings for steel structures be selected and inspected?


Release date:

2023-01-06

Author:

Zhengxiang Fireproof Materials

How should fire-resistant coatings for steel structures be selected and accepted? Currently, fire-resistant coatings for steel structures are increasingly recognized and adopted as a fire protection measure for steel structures due to their ease of application, reliable performance, and cost-effectiveness.

   Fireproof coating for steel structures How to select and accept?

  

 Fireproof coating for steel structures


  Currently, steel structure fireproof coatings are increasingly recognized and adopted as fire protection measures for steel structures due to their ease of application, reliable performance, and cost-effectiveness. So, for a steel structure project, how should one select an appropriate fireproof coating? The selection principles are as follows:

  There are many types of fire‑protective coatings for steel structures; however, for any specific steel‑structure fire‑protection project, it is essential to select the appropriate type of coating, which is a prerequisite for practical application. Based on the fire‑protection design requirements—such as the fire hazard level of the protected object, the location where the coating will be applied, the required fire‑resistance rating, and the specified fire‑resistance duration for each structural component—and in accordance with standards like Technical Code for Fire Protection of Steel Structures GB 51249-2017 and Technical Specification for Application of Fire‑Protective Coatings for Steel Structures TCECS 24-2020, the suitable coating for each building element is determined. For example, consider a Class B steel‑structure industrial plant with the following fire‑protection design: fire resistance class II; fire‑resistance duration of 2.5 hours for steel columns and intercolumnar bracings; 1.5 hours for steel beams and steel staircases; and 1 hour for other roof load‑bearing members.

  Therefore, the steel columns and intercolumnar bracings should be protected with a standard indoor non‑intumescent fire‑protective coating for steel structures having a 2.5‑hour fire resistance rating, namely GT‑NSF‑Fp2.50‑. Reason: This type of fire‑protective coating for ordinary steel structures in industrial buildings provides protection against Class B ordinary fire hazards; it is applied to steel columns within workshops, using fire‑protective coatings on interior steel members; and it offers a 2.5‑hour fire resistance rating. Fireproof coating for steel structures Non‑intumescent fire‑protective coatings with a fire resistance rating of 2.5 hours or more should be selected. For steel beams and staircases, an intumescent interior fire‑protective coating for steel structures with a 1.5‑hour fire resistance rating—namely GT‑NSP‑FP 1.00—should be used. Reason: To protect the steel beams and staircases within the plant, fire‑protective coatings are applied to interior steel structures; since the required fire resistance is 1.0 hour, an intumescent coating is chosen because non‑intumescent types are difficult to apply. A waterborne coating is preferred over solvent‑based formulations due to environmental concerns, and the coating must provide a fire resistance of at least 1.0 hour. And so on.

  Once the specific fire‑protective coating model has been selected, priority should be given to reputable products that have been certified by a nationally designated certification body (i.e., hold the required statutory certificates), enjoy a high market share in the industry, demonstrate reliable product quality, and are accompanied by complete quality documentation.

  The following reports shall be provided for the acceptance inspection of fire-resistant coatings for steel structures:

  (1) Design documents and changes for fireproof coating projects;

  (2) Type inspection report or type test report, together with the factory certificate of conformity;

  (3) Construction Operation Instruction;

  (4) Coating incoming inspection report;

  (5) Compatibility test report for anti-rust paint and fireproof paint;

  (6) Records of pre-treatment measures for fireproof coatings on galvanized steel components;

  (7) Records of treatment for rust reoccurrence or damage to anti-rust paint on steel structures;

  (8) Concealing inspection and acceptance records for engineering inspection items;

  (9) Quality acceptance records for each inspection batch within the fireproof coating sub-project;

  (10) Construction Site Quality Management Inspection Records;

  (11) Other necessary documents and records.